Part Number Hot Search : 
UM810AEP SFH6136 VCX162 TPCA8025 TPCA8025 C1321 DA726 T1100
Product Description
Full Text Search
 

To Download B84143A0110R410 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 3-line filters for converters and power electronics
520/300 V, 50/60 Hz, 35 ... 230 A, 50 C
Ordering code: Date: Version:
B84143A*R410, B84143B*R410 2009-08-03 02
(c) EPCOS AG 2008. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.
3-line filters for converters and power electronics
B84143A*R410, B84143B*R410
Construction S 3-line filter S Metal case S Book size Features S High insertion loss S Easy to install S Compact design S Degree of protection IP 20 1) S Design complies with IEC 60939, UL 1283, CSA 22.2 No.8 S Optimized for long motor cable and operation under full load S B84143A*R410: UL- and cUL approval Applications S Frequency converters and regenerative frequency converters (AFE) for motor drives, e.g. - elevators - machine tool building - pumps - traction systems - conveyor systems - HVAC systems (heating, ventilation and air conditioning) Terminals S Finger-save terminal blocks Marking S Marking on component: manufacturer's logo, ordering code, rated voltage, rated frequency, rated current, rated temperature, climatic category, date code S Minimum marking on packaging: manufacturer's logo, ordering code, date code, quantity
1)
To IEC 60529:2001
Please read Important notes and Cautions and warnings at the end of this document.
Page 2 of 14
B84143-*-R410-02-7659
3-line filters for converters and power electronics
B84143A*R410, B84143B*R410
Typical circuit diagram of B84143A0035R410, B84143A0200R410, B84143A0230R410 LINE LOAD
Typical circuit diagram of B84143A0050R410, B84143A0080R410, B84143A0110R410, B84143A0150R410 LINE LOAD
Typical circuit diagram of B84143B0200R410, B84143B0230R410 LINE LOAD
Please read Important notes and Cautions and warnings at the end of this document.
Page 3 of 14
B84143-*-R410-02-7659
3-line filters for converters and power electronics
B84143A*R410, B84143B*R410
Technical data and measuring conditions Rated voltage Rated frequency Test voltage line to line for 2 s Test voltage line to case for 2 s Rated temperature Overload capability (thermal) for 3 min per hour or for 30 s per hour Climatic category (IEC 60068-1) UR fR Utest Utest TR 520/300 50/60 2240 2720 50 1.5 x IR 2.5 x IR 25/100/21 V AC Hz V DC V DC C
Characteristics and ordering codes UR AC V 520/300 IR Terminal Ileak 2) cross section mm2 mA 35 50 80 110 150 200 230 200 230 10 25 50 50 95 95 95 95 95 14 15 15 15 15 10 10 18 18 Rtyp Approx. Ordering code weight kg 2.5 4.5 8.5 9.0 13.5 14.0 14.5 19.0 19.0 B84143A0035R410 B84143A0050R410 B84143A0080R410 B84143A0110R410 B84143A0150R410 B84143A0200R410 B84143A0230R410 B84143B0200R410 B84143B0230R410 X X X X X X X - - X X X X X X X - - Approvals
A
m 2.9 1.6 0.9 0.65 0.6 0.3 0.25 0.39 0.35
X = approval granted
2) Calculation according draft proposal IEC 60939-1 Ed. 3 (2008-10-29), annex A, "Calculation of leakage current".
Please read Important notes and Cautions and warnings at the end of this document.
Page 4 of 14
B84143-*-R410-02-7659
3-line filters for converters and power electronics
B84143A*R410, B84143B*R410
Dimensional drawings B84143A0035R410
Terminals 10mm2 Tightening torque 1.5 - 1.8Nm
Terminals 10mm2 Tightening torque 1.5 - 1.8Nm
PE M5 x 19 Tightening torque 2"0.1Nm
PE M5 x 19 Tightening torque 2"0.1Nm
View A
Line Load
Marking
All dimensions in mm
Please read Important notes and Cautions and warnings at the end of this document.
Page 5 of 14
B84143-*-R410-02-7659
3-line filters for converters and power electronics
B84143A*R410, B84143B*R410
B84143A0050R410
PE M6 x 23.5 Tightening torque 3$0.15mm
PE M6 x 23.5 Tightening torque 3$0.15mm
Line
Load
View A
Terminals 25mm2 Tightening torque 4 - 4.5Nm Terminals 25mm2 Tightening torque 4 - 4.5Nm
Marking
All dimensions in mm
Please read Important notes and Cautions and warnings at the end of this document.
Page 6 of 14
B84143-*-R410-02-7659
3-line filters for converters and power electronics
B84143A*R410, B84143B*R410
B84143A0080R410, B84143A0110R410
PE M10 x 38 Tightening torque 10$1mm Line Load
PE M10 x 38 Tightening torque 10$1mm
Terminals 50mm2 Tightening torque 6-8Nm
Terminals 50mm2 Tightening torque 6-8Nm
Marking
All dimensions in mm
Please read Important notes and Cautions and warnings at the end of this document.
Page 7 of 14
B84143-*-R410-02-7659
3-line filters for converters and power electronics
B84143A*R410, B84143B*R410
B84143A0150R410, B84143A0200R410, B84143A0230R410
PE M10 x 38 Tightening torque 10$1mm Line Load
PE M10 x 38 Tightening torque 10$1mm
Terminals 95mm2 Tightening torque 15-20Nm
Terminals 95mm2 Tightening torque 15-20Nm
Marking
All dimensions in mm
Please read Important notes and Cautions and warnings at the end of this document.
Page 8 of 14
B84143-*-R410-02-7659
3-line filters for converters and power electronics
B84143A*R410, B84143B*R410
B84143B0200R410, B84143B0230R410
PE M10 x 38.5 Tightening torque 10$1mm
PE M10 x 38.5 Tightening torque 10$1mm
Terminals 95mm2 Tightening torque 15-20Nm
View A
Line
Load
Terminals 95mm2 Tightening torque 15-20Nm
Marking
All dimensions in mm
Please read Important notes and Cautions and warnings at the end of this document.
Page 9 of 14
B84143-*-R410-02-7659
3-line filters for converters and power electronics
B84143A*R410, B84143B*R410
Insertion loss (typical values at Z = 50 W) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical)
B84143A0035R410 100 dB a 80 a 80 100 dB
B84143A0050R410
60 40 20
60 40 20
0 104
105
106
107 f
Hz 108
0 104
105
106
107 f
Hz 108
B84143A0080R410 100 dB a 80 a 80 100 dB
B84143A0110R410
60 40
60 40
20
20
0 104
105
106
107 f
Hz 108
0 104
105
106
107 f
Hz 108
Please read Important notes and Cautions and warnings at the end of this document.
Page 10 of 14
B84143-*-R410-02-7659
3-line filters for converters and power electronics
B84143A*R410, B84143B*R410
Insertion loss (typical values at Z = 50 W) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical)
B84143A0150R410 100 dB a 80 a 80 100 dB
B84143A0200R410
60 40 20
60 40 20
0 104
105
106
107 f
Hz 108
0 104
105
106
107 f
Hz 108
B84143A0230R410 100 dB a 80
60 40
20
0 104
105
106
107 f
Hz 108
Please read Important notes and Cautions and warnings at the end of this document.
Page 11 of 14
B84143-*-R410-02-7659
3-line filters for converters and power electronics
B84143A*R410, B84143B*R410
Insertion loss (typical values at Z = 50 W) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical)
B84143B0200R410 100 dB a 80 a 80 100 dB
B84143B0230R410
60 40 20
60 40 20
0 104
105
106
107 f
Hz 108
0 104
105
106
107 f
Hz 108
Please read Important notes and Cautions and warnings at the end of this document.
Page 12 of 14
B84143-*-R410-02-7659
3-line filters for converters and power electronics
B84143A*R410, B84143B*R410
Caution and warnings S Please note the advices in our data book "EMC Filters" (latest edition); attention should be paid to the chapter "General safety notes". S It shall be ensured that only qualified persons (electricity specialists) are engaged on work such as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. S Danger of electric shock. EMC filters contain components that store an electric charge. Dangerous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. S The protective earth connections shall be the first to be made when the EMC filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. S Impermissible overloading of the EMC filter, such as with circuits able to cause resonances, impermissible voltages at higher frequencies etc. can lead to bodily injury and death as well as cause substantial material damages (e.g. destruction of the filter housing). S EMC filters must be protected in the application against impermissible exceeding of the rated currents by overcurrent protective. S In case of leakage currents > 3.5 mA you shall mount the PE conductor stationary with the required cross section before beginning of operation and save it against disconnecting. For leakage currents IL 4) < 10 mA the PE conductor must have a KU value 3) of 4.5; for leakage currents IL q 10 mA the PE conductor must have a KU value of 6.
3) The KU value (symbol KU) is a classification parameter of safety-referred failure types designed to ensure protection against hazardous body currents and excessive heating. A value of KU = 4.5 with respect to interruptions is attained: - with a permanently connected protective earth circuit w 1.5 mm2 - with a protective earth circuit w 2.5 mm2 connected via shroud connectors (IEC 60309-2). KU = 6 with respect to interruptions is achieved for fixed-connection lines w 10 mm2 where the type of connection and line layout correspond to the requirements for PEN conductors as specified in relevant standards. 4) IL = leakage current let-go
Please read Important notes and Cautions and warnings at the end of this document.
Page 13 of 14
B84143-*-R410-02-7659
Important notes
The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DSSP, MiniBlue, MiniCell, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.
Page 3 of 3


▲Up To Search▲   

 
Price & Availability of B84143A0110R410

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X